- CVSS 7.2 High
Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability
- Triangle MicroWorks SCADA Data Gateway
- Path traversal
- CVSS 7.2 High
Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability
- Triangle MicroWorks SCADA Data Gateway
- CWE-749
- CVSS 5.3 Medium
Triangle MicroWorks SCADA Data Gateway certificate Information Disclosure Vulnerability
- Triangle MicroWorks SCADA Data Gateway
- CWE-219
- CVSS 5.3 Medium
Triangle MicroWorks SCADA Data Gateway get_config Missing Authentication Information Disclosure Vulnerability
- Triangle MicroWorks SCADA Data Gateway
- Authentication bypass
- CVSS 7.5 High
Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Cryptograhic Key Information Disclosure Vulnerability
- Triangle MicroWorks SCADA Data Gateway
- Hard-coded credentials
- CVSS 7.2 High
Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability
- Triangle MicroWorks SCADA Data Gateway
- CWE-428
- CVSS 7.2 High
Triangle MicroWorks SCADA Data Gateway Trusted Certification Unrestricted Upload of File Remote Code Execution Vulnerability
- Triangle MicroWorks SCADA Data Gateway
- Unrestricted file upload
- CVSS 6.5 Medium
Triangle MicroWorks SCADA Data Gateway Workspace Unrestricted Upload Vulnerability
- Triangle MicroWorks SCADA Data Gateway
- Unrestricted file upload
- CVSS 4.4 Medium
Triangle MicroWorks SCADA Data Gateway Event Log Improper Output Neutralization For Logs Arbitrary File Write Vulnerability
- Triangle MicroWorks SCADA Data Gateway
- Other injection
- CVSS 7.2 High
Triangle MicroWorks SCADA Data Gateway Event Log Directory Traversal Arbitrary File Creation Vulnerability
- Triangle MicroWorks SCADA Data Gateway
- Path traversal
- CVSS 7.8 High
Triangle MicroWorks SCADA Data Gateway Directory Traversal Arbitrary File Creation Vulnerability
- Triangle MicroWorks SCADA Data Gateway
- Path traversal
- CVSS 5.3 Medium
Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Credentials Authentication Bypass Vulnerability
- Triangle MicroWorks SCADA Data Gateway
- Hard-coded credentials
- CVSS 9.8 CriticalCritical · CVSS 9+
Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability
- Triangle MicroWorks SCADA Data Gateway
- Authentication bypass
- CVSS 5.3 Medium
Missing authentication in Triangle MicroWorks SCADA Data Gateway
- Triangle MicroWorks SCADA Data Gateway
- Authentication bypass
- CVSS 8.2 High
Uncontrolled format string in Triangle MicroWorks SCADA Data Gateway
- Triangle MicroWorks SCADA Data Gateway
- Memory corruption
- CVSS 1.2 Low
Triangle MicroWorks SCADA Data Gateway Resource Exhaustion
- Triangle MicroWorks SCADA Data Gateway
- Denial of service
- CVSS 4.3 Medium
Triangle MicroWorks SCADA Data Gateway Resource Exhaustion
- Triangle MicroWorks SCADA Data Gateway
- Denial of service