Advisories · Technology
Siemens APOGEE PXC Modular (BACnet).
Every CVE that names Siemens APOGEE PXC Modular (BACnet) among its affected products, newest first. Vendors and products are as the CNA wrote them; check the affected versions on each record.
- CVSS 8.7 High
Stack-based buffer overflow in Siemens APOGEE MBC (PPC) (BACnet) and others
- Siemens APOGEE MBC (PPC) (BACnet)
- Siemens APOGEE MBC (PPC) (P2 Ethernet)
- Memory corruption
- CVSS 8.7 High
Stack-based buffer overflow in Siemens APOGEE MBC (PPC) (BACnet) and others
- Siemens APOGEE MBC (PPC) (BACnet)
- Siemens APOGEE MBC (PPC) (P2 Ethernet)
- Memory corruption
- CVSS 8.7 High
Stack-based buffer overflow in Siemens APOGEE MBC (PPC) (BACnet) and others
- Siemens APOGEE MBC (PPC) (BACnet)
- Siemens APOGEE MBC (PPC) (P2 Ethernet)
- Memory corruption
- CVSS 8.8 High
Integer underflow in Siemens APOGEE MBC (PPC) (BACnet) and others
- Siemens APOGEE MBC (PPC) (BACnet)
- Siemens APOGEE MBC (PPC) (P2 Ethernet)
- Memory corruption
- CVSS 8.8 High
Improper access control in Siemens APOGEE PXC Compact (BACnet) and others
- Siemens APOGEE PXC Compact (BACnet)
- Siemens APOGEE PXC Compact (P2 Ethernet)
- Broken access control
- CVSS 8.7 High
Uncontrolled resource consumption in Siemens APOGEE MBC (PPC) (BACnet) and others
- Siemens APOGEE MBC (PPC) (BACnet)
- Siemens APOGEE MBC (PPC) (P2 Ethernet)
- Denial of service
-
Improper null termination in Siemens APOGEE MBC (PPC) (BACnet) and others
- Siemens APOGEE MBC (PPC) (BACnet)
- Siemens APOGEE MBC (PPC) (P2 Ethernet)
- CWE-170
-
Improper null termination in Siemens APOGEE MBC (PPC) (BACnet) and others
- Siemens APOGEE MBC (PPC) (BACnet)
- Siemens APOGEE MBC (PPC) (P2 Ethernet)
- CWE-170
-
Improper null termination in Siemens APOGEE MBC (PPC) (BACnet) and others
- Siemens APOGEE MBC (PPC) (BACnet)
- Siemens APOGEE MBC (PPC) (P2 Ethernet)
- CWE-170
-
Siemens APOGEE MBC (PPC) (BACnet): A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions)…
- Siemens APOGEE MBC (PPC) (BACnet)
- Siemens APOGEE MBC (PPC) (P2 Ethernet)
- Memory corruption
-
Improper null termination in Siemens APOGEE MBC (PPC) (BACnet) and others
- Siemens APOGEE MBC (PPC) (BACnet)
- Siemens APOGEE MBC (PPC) (P2 Ethernet)
- CWE-170
- CVSS 9.8 CriticalCritical · CVSS 9+
Buffer overflow in Siemens APOGEE MBC (PPC) (P2 Ethernet) and others
- Siemens APOGEE MBC (PPC) (P2 Ethernet)
- Siemens APOGEE MEC (PPC) (P2 Ethernet)
- Memory corruption
- CVSS 5.3 Medium
Insufficiently random values in Siemens APOGEE PXC Compact (BACnet) and others
- Siemens APOGEE PXC Compact (BACnet)
- Siemens APOGEE PXC Compact (P2 Ethernet)
- Weak cryptography or TLS
- CVSS 6.5 Medium
Siemens APOGEE PXC Compact (BACnet): A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions <…
- Siemens APOGEE PXC Compact (BACnet)
- Siemens APOGEE PXC Compact (P2 Ethernet)
- Memory corruption
- CVSS 6.5 Medium
Out-of-bounds read in Siemens APOGEE PXC Compact (BACnet) and others
- Siemens APOGEE PXC Compact (BACnet)
- Siemens APOGEE PXC Compact (P2 Ethernet)
- Memory corruption
- CVSS 6.5 Medium
Improper null termination in Siemens APOGEE PXC Compact (BACnet) and others
- Siemens APOGEE PXC Compact (BACnet)
- Siemens APOGEE PXC Compact (P2 Ethernet)
- CWE-170
- CVSS 8.1 High
Siemens APOGEE PXC Compact (BACnet): A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions <…
- Siemens APOGEE PXC Compact (BACnet)
- Siemens APOGEE PXC Compact (P2 Ethernet)
- CWE-823
- CVSS 8.1 High
Out-of-bounds write in Siemens APOGEE PXC Compact (BACnet) and others
- Siemens APOGEE PXC Compact (BACnet)
- Siemens APOGEE PXC Compact (P2 Ethernet)
- Memory corruption
- CVSS 6.5 Medium
Siemens APOGEE PXC Compact (BACnet): A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions <…
- Siemens APOGEE PXC Compact (BACnet)
- Siemens APOGEE PXC Compact (P2 Ethernet)
- CWE-342
- CVSS 7.1 High
Improper input validation in Siemens APOGEE MEC/MBC/PXC (P2) and others
- Siemens APOGEE MEC/MBC/PXC (P2)
- Siemens APOGEE PXC Compact (BACnet)
- CWE-20