- [Life2000 ventilator and Service PC lack sufficient audit logging capabilities](https://agentprime.io/advisories/CVE-2024-48967.md)
  `CVE-2024-48967` · CVE record: Baxter Life2000 Ventilation System · CVSS 10.0 Critical · Critical (CVSS 9+) · Not analysed yet · Published 14 Nov 2024 · Tags: CWE-778
- [Life2000 service tools for test and calibration do not support user authentication](https://agentprime.io/advisories/CVE-2024-48966.md)
  `CVE-2024-48966` · CVE record: Baxter Life2000 Ventilation System · CVSS 10.0 Critical · Critical (CVSS 9+) · Not analysed yet · Published 14 Nov 2024 · Tags: Authentication bypass
- [Life2000 Ventilator microcontroller lacks memory protection](https://agentprime.io/advisories/CVE-2024-48970.md)
  `CVE-2024-48970` · CVE record: Baxter Life2000 Ventilation System · CVSS 9.3 Critical · Critical (CVSS 9+) · Not analysed yet · Published 14 Nov 2024 · Tags: CWE-1191
- [Life2000 Ventilator does not perform proper file integrity checks when adopting firmware updates](https://agentprime.io/advisories/CVE-2024-48974.md)
  `CVE-2024-48974` · CVE record: Baxter Life2000 Ventilation System · CVSS 9.3 Critical · Critical (CVSS 9+) · Not analysed yet · Published 14 Nov 2024 · Tags: CWE-494
- [Debug port on Life2000 Ventilator serial interface is enabled by default](https://agentprime.io/advisories/CVE-2024-48973.md)
  `CVE-2024-48973` · CVE record: Baxter Life2000 Ventilation System · CVSS 9.3 Critical · Critical (CVSS 9+) · Not analysed yet · Published 14 Nov 2024 · Tags: CWE-1263
- [Clinician Password and Serial Number Clinician Password are hard-coded in Life2000 Ventilator](https://agentprime.io/advisories/CVE-2024-48971.md)
  `CVE-2024-48971` · CVE record: Baxter Life2000 Ventilation System · CVSS 9.3 Critical · Critical (CVSS 9+) · Not analysed yet · Published 14 Nov 2024 · Tags: Hard-coded credentials
- [No limit on failed login attempts with Clinician Password or Serial Number Clinician Password on Life2000 Ventilator](https://agentprime.io/advisories/CVE-2024-9832.md)
  `CVE-2024-9832` · CVE record: Baxter Life2000 Ventilation System · CVSS 9.3 Critical · Critical (CVSS 9+) · Not analysed yet · Published 14 Nov 2024 · Tags: Authentication bypass
- [Improper data protection on Life2000 ventilator serial interface](https://agentprime.io/advisories/CVE-2024-9834.md)
  `CVE-2024-9834` · CVE record: Baxter Life2000 Ventilation System · CVSS 9.3 Critical · Critical (CVSS 9+) · Not analysed yet · Published 14 Nov 2024 · Tags: Weak cryptography or TLS

## Filters and formats

Filters are query parameters on this URL: `q` (words, as in a web search engine: `"a phrase"`, `OR`, `-word`; an id; a package or product name), `severity` (low, medium, high or critical), `critical=1`, `kev=1`, `ecosystem` (npm, pypi, packagist, go, maven, rubygems, crates, nuget, hex), `kind=package`, `assigner` (a CNA’s short name), `min_score` and `state`. Each record’s title links to its Markdown page.

- The same list as JSON: <https://api.agentprime.io/v1/advisories?technology=baxter-life2000-ventilation-system>
- Every list: <https://agentprime.io/advisories.md>, critical: <https://agentprime.io/advisories/critical.md>; by weakness: <https://agentprime.io/advisories/tag/sql-injection.md> and the other tags in <https://agentprime.io/llms.txt>; by technology: `/advisories/technology/<slug>.md` (`fortinet-fortimail`)

---

The web page: <https://agentprime.io/advisories/technology/baxter-life2000-ventilation-system/>. Everything for agents: <https://agentprime.io/llms.txt>.